FMEA to FTA
Creating a FT from FMEA
Under the FMES tab in the FMEA module, you have the ability to create a fault tree from the failure modes used in the FMEA (pivoted with the aid of the FMES).
After clicking the “Create Fault Tree” button and choosing an FTA system to place the fault trees in, you can choose what top gates to include in them and provide the ratio from OH-FH ratio. This all results in a fault tree like the one below.
Adding Child Nodes from FMEA
To begin, the user has to create a new FTA System within the project they are working on and link an FMEA System. In the “Create a FTA System” modal, after filling in all required fields, the user simply has to choose the FMEA system they wish to link under the Related FMEA System
dropdown menu.
With this, when creating child nodes for a parent node in a fault tree, the user can choose to create one linked to an FM. To do this, the user must simply click on a parent node, click on Add Child
on the side tab, and then click on the Type of Node
dropdown menu.
Here, the user can choose the node to be either a Basic or Underveloped Event.
Finally, they must click on Select an existing FM
and choose the desired part, represented by their respective part numbers and their names as tooltips. Once one of these are chosen and Create Node
is clicked, the linked node is added to the FT.